Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U

ACREL CO., LTD.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive Protection Functions: Includes overcurrent, earth fault, negative sequence, over/under voltage, and PT supervision with IDMT stages.
  • Flexible Power Supply Options: Supports AC/DC220V, AC/DC1110V, DC48V, and DC24V for versatile installation environments.
  • Advanced Communication Protocols: Features RS485 ports supporting Modbus serial and IEC 60870-5-103 protocols for seamless integration.
  • Detailed Measurement Capabilities: Monitors electric parameters including voltage, current, power, power factor, frequency, and energy.
  • Robust Data Logging: Equipped with fault recorder and sequence of event record for precise troubleshooting and analysis.
  • Wide Application Range: Suitable for substations, ring main units, and various buildings with input voltage up to 35kV.
  • Full Customization Support: Offers full customization, minor customization, and flexible customization from samples or designs.
  • ISO Certified Manufacturing: Manufactured under ISO9001, ISO45001, and ISO14001 standards with 100% finished product inspection.

Product Images of Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U

Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U pictures & photos
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U pictures & photos
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U pictures & photos
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U pictures & photos
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U pictures & photos
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U pictures & photos
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
    Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
    Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
    Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
    Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
    Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
  • Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
    Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U

Find Similar Products

Product Description

Product Description


AM series protection relay are applicable to the user substation which the input voltage is 35kv and below. We adopt mature technology solutions to ensure the quality of the AM relay.The AM relay are widely used in substations, subsection posts and ring main units for office buildings, commercial buildings, communication buildings, mine buildings and so on.
 
Protection functions
AM3SE-I
AM3SE-U
Overcurrent (3 stages,IDMT)
√
 
Earth fault (3 stages,IDMT)(I01/I02)
√
 
Negative sequence overcurrent (2 stages,IDMT)
√
 
Auto-reclose
√
 
Overload (trip/alarm)
√
 
Under frequency
√
 
Post-accelerated overcurrent
√
 
Post-accelerated overcurrent(I01/I02)
√
 
Overvoltage(trip)
√
 
Undervoltage (trip)
√
 
Self-produced over zero-voltage (trip)
√
 
Residual overvoltage (trip)
√
 
FC block
√
 
Trip and close circuit supervision (alarm)
√
 
Non-electricity (trip/alarm)
√
 
Undervoltage (alarm)
√
√
Overvoltage (alarm)
√
√
Residual overvoltage (alarm)
√
√
PT supervision (alarm)
√
√
Self-produced over zero-voltage (alarm)
 
√
Rear ports
I
U
RS485
√
Protocols
I
U
Modbus serial
√
 
IEC 60870-5-103
√
Measurement
I
U
Electric parameter
U,I,P,Q,PF,Fr,Ep,Eq,Es
Input Current
5
5
Input Voltage
3
3
Logs and Records
I
U
Fault recorder
√
Sequence of event record
√
Monitoring Functions
I
U
Anti-pumping circuit
Optional
 
Remote control
√


Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U


Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
 

Typical Connection

 


Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U

Site Picture


Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U

FAQ

Q: How to set the CT and PT ratio of the protection device?

A:The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and
the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.

Q: How to distinguish the model when place order of AM3SEthat a single line protection and transformer protection?

A: A AM3SE is suitable for circuit protection and transformerprotection. No need to distinguish between models when placing
orders.

Q: When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.

Q: How to confirm whether the anti-trip function is configured?

A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)

Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U

Customer
Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U


 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR244735". Items marked "verified" are certified.

Watch Video
Watch Video
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 253 Yulv Road, Jiading District, Shanghai, China
verified Plant Area
15811.7 square meters
verified Number of Employees
291
verified Registered Capital
214,716,125 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
1500

Our Production Capability & Technical Expertise

verified Main Products
Energy Meter, Transformer Current, Temperature&Humidity Controller, Medical It System, Active Power Filter, Static Var Generator, Charging Pile
verified Production Lines
18
verified Production Machines
SMT Production Line, DIP Assembly Line, Automatic Electricity Sensor Production Line, Automatic Debugging and Testing Equipment
verified QA/QC inspectors
73 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified R&D Engineers
131 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2003-06-23
verified Export Year
4 Years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Australia, Domestic
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
50
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

How to set the CT and PT ratio of the protection device?
The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.
How to distinguish the model when place order of AM3SEthat a single line protection and transformer protection?
A AM3SE is suitable for circuit protection and transformerprotection. No need to distinguish between models when placing orders.
When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?
The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.
How to confirm whether the anti-trip function is configured?
If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)
How to purchase suitable protection devices?
Before ordering, it is recommended to consult related engineers, select the appropriate protection model, and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now