Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail
  • Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail
  • Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail
  • Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail
  • Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail
  • Acrel Potentiometer Input Isolation Safety Barrier Increases The System′s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
BM200-VR/I-C12
Output Signal Type
Analog Output
Accuracy Grade
0.2g
IP Rating
IP20
Trademark
Acrel
Origin
China

Product Description

Product Description

BM200 isolated safety barrier can transmit signals between the safe area and the dangerous area, and limit the energy transfer from the safe area to the dangerous area caused by the fault. The voltage, current, temperature, resistance signals generated by the equipment (transmitter) on the dangerous side are isolated and converted into corresponding linear voltage and current signals outputting to the safe area. The product requires independent power supply, and the input/output/power supply is isolated. It can be used in current source, two-wire, three-wire transmitter equipment. DC voltage/current input Using magnetic isolation technology Response time <400ms TS35 rail installation Plug-in terminal Temperature drift coefficient: ≤200ppm/ºC at 0.5 level.
 

Product Parameters
Channel type
Single-way input and single-way output,
single-way input and double-way output,
double-way input and double-way output
Input type
Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple
Input signal
0~20mA /4~20mA
0~5V /0~10V /1~5V (Distribution voltage: 12V/20mA)
PT100 /0~10K/K,E,T,J,N,R,S,B
Output signal
0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω
0~5V /1~5V (Safe side input); Load resistance: ≥330K
0~10V (Safe side input); Load resistance: ≥500K
Transmission accuracy
0.20%
Temperature modulus
50ppm/ºC (The output signal is current)
Response time
5ms to reach 90% of final value
(RTD Pt100/resistance/thermocouple input: 1s to reach 90% of final value)
Power supply
20~35V DC
Work temperature
-20ºC~+60ºC
Fix mode
Rail installation
Dielectric strength
Intrinsically Safe and Non-Intrinsically Safe ≥2500V AC; Power supply and
Non-Intrinsically Safe ≥500V AC
Note:Intrinsically Safe is input, Non-Intrinsically is output
 Acrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN RailAcrel Potentiometer Input Isolation Safety Barrier Increases The System&prime;s Anti-Interference Ability Bm200-Vr/I-C12 DIN Rail

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier