Customization: | Available |
---|---|
Application: | Electronic |
Type: | Current Transformer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hall current sensors are mainly suitable for the isolation and conversion of complex signals such as AC, DC, and pulse. Through the principle of Hall effect, the converted signals can be directly collected and accepted by various acquisition devices such as AD, DSP, PLG, and secondary instruments. They are widely used in current monitoring and battery applications, inverter power supply and solar power management systems, DC panels and DC motor drives, electroplating, welding applications, frequency converters, UPS servo control and other system current signal acquisition and feedback control. They have the advantages of fast response time, wide current measurement range, high accuracy, strong overload capacity, good linearity, and strong anti-interference ability.
Type
|
Rated current ratio(A)
|
Rated Output
|
Power Supply
|
AHKC-EKBA
|
DC0~(20-1000)A
|
4-20mA
|
12V/24V
|
Parameters
|
Index
|
Rated Input Current
|
DC0~(20-1000)A
|
Rated Output Voltage
|
4-20mA
|
Accuracy Class
|
1.0
|
Power Voltage
|
12V/24V
|
Zero Offset Voltage
|
±20mV
|
Offset Voltage Drift
|
≤±1.0mV/ºC
|
Linearity
|
≤0.2%FS
|
Response Time
|
≤5us
|
Bandwidth
|
0~20kHz
|
Isolation Voltage
|
3.5kV/50Hz/1min
|
Operating Temperature
|
-40ºC~85ºC
|
Storage Temperature
|
-40ºC~85ºC
|
Consumption
|
≤0.5W
|
Environment |
Temperature
|
Operating Temperature: -25~+50ºC Storing Temperature: -40~+80ºC
|
Humidity
|
≤90%(No condensation)
|
|
Altitude
|
≤2500m
|