Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input

Product Details
Customization: Available
After-sales Service: 2 Years
Usage: Multi-Functional Energy Meter
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input
  • Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input
  • Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input
  • Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input
  • Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input
  • Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Certifications
Overview

Basic Info.

Model NO.
AMC16Z-ZA
Theory
Electronic Meter
Electric Equipment
Three-Phase Four-Wire
Power Meter Connection
Terminal
Trademark
Acrel
Origin
China

Product Description

Product Description

AMC16Z series AC precision power distribution monitoring device is specially designed for data center server power management.The device designed exquisite, can provide A + B 2 incoming and 96 outgoing's electrical parameters, the input and output switch and the state of lightning protection device with real-time monitoring. All alarm threshold of measurement channels can be set in separate. Over-outgoing triggers system acoustooptic warning immediately. Highly integrated monitoring loop is realized in the volume of traditional instruments.
Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input

Product Parameters
Type Model
Function description


AMC16Z-ZA
Monitor the full power parameters of A+B double-way three-phase AC incoming circuit, 6-way switch state monitoring, 2-way alarm
output, 2-way leakage monitoring, 1-way temperature and humidity detection, 1-way RS485
communication, and phase-sequence detection.


AMC16Z-FA
Monitor the full power parameters of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase
adjustment.
AMC16Z-KA
Wet contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.
AMC16Z-KD
Dry contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.


AMC16Z-FAK24
Monitor the full power parameters and switch state of 24 branches of A+B double- way AC outgoing line, 1-way RS485 communication
and phase adjustment.


AMC16Z-FAK48
Monitor the full power parameters and switch state of 48 branches of A+B double- way AC outgoing line, 1-way RS485 communication
and phase adjustment.


AMC16Z-FDK24
Monitor the full power parameters and switch state of 24 branches of A+B double-way DC outgoing line, 1-way RS485 communication
and phase adjustment.


AMC16Z-FDK48
Monitor the full power parameters and switch state of 48 branches of A+B double-way DC outgoing line, 1-way RS485 communication
and phase adjustment.
Function
Description
Measurement
(Common)
Three-phase AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparent Power, Frequency, Zero ground
voltage, neutral line current
Measurement
(Power Quality)
total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest
coefficient (CF), telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity
Temp.&Humidity
Monitoring
Temperature Monitoring Range: -40ºC~+99ºC
Humidity Monitoring Range: 20%~90%
Leakage Current
2-channel Leakage Current Measurement
Accuracy
Electrical Parameter Metering Accuracy: Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric
energy level 1

Temperature Metering Accuracy: ±1ºC; Temperature Metering Accuracy: ±5%
Communication
RS485 Interface (MODBUS-RTU protocol)
DO
(Switch Output)
2-channel DO (Digital Output); 3A 250VAC/3A 30VDC
DI
(Switch Input)
6-channel DI (Digital Input); dry contact
Parameter
Description&Value
Voltage
Input
Rated Voltage
3x220~264Vac L-N
Reference Frequency
45~65Hz
Current
Input
Rated Current
3x1(6)A AC (via CTs)
Power
Supply
Source from
Voltage Input (Voltage signal input for both measurement and power supply)
Installation
DIN-rail
35mm standard DIN-rail Installation
Phase
Wiring
3P4W
3-phase 4-wire
Safety
Insulation
All terminals and the insulation resistance between the conductive pieces not less than 100MΩ
Withstand voltage
A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs,
the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover
Condition
Description&Value
Temperature
Operating Temperature: -20ºC~+55ºC; Storage Temperature: -40°C ~+70°C
Humidity
≤95%RH, no condensation, without corrosive gas
Altitude
≤ 2000m
Installation Instructions

Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch InputAcrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch InputAcrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input

Certifications

Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier