Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485
  • Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485
  • Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485
  • Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485
  • Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485
  • Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
AMC100-FAK48
Usage
Multi-Function Energy Meter
Theory
Electronic Meter
Electric Equipment
Three Phase Four Wire
Power Meter Connection
Terminal
Trademark
Acrel
Origin
China

Product Description

Product Description

AMC Precision Power Distribution Monitoring Solution is a complete solution designed and developed for the monitoring requirements of precision power distribution cabinets (column head cabinets), including AC 220V and DC 48V/240V/336V systems: Composed of ≥ 7-inch touch LCD display screen, integrated information processing host module, switch status acquisition module, current transformer or Hall sensor acquisition unit module, etc AMC100 Precision Power Distribution Monitoring: Cabling and unplugging method, transformer rail installation, single module 30/48 circuits, system supports up to 4 incoming and 192 outgoing circuit monitoring.
 

Product Parameters
Type Model
Function description
AMC100-ZA
Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching
status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications


AMC100-FAK30
Monitor the full power parameters and switch status of a total of 30branches of A+B dual AC outlets, and 1 RS485 communication


AMC100-FAK48
Monitor the full power parameters and switch status of a total of48branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FA30
Monitor the full power parameters of a total of 30branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FA48
Monitor the full power parameters of a total of48branches of A+B dual AC outlets, and 1 RS485 communication


AMC100-KA30
Wet contact, monitor the switching status of 30branches A+B, 1 RS485 communication


AMC100-KA48
Wet contact, monitor the switching status of 48branches A+B, 1 RS485 communication


AMC100-KD30
Dry contact, monitor the switching status of 30branches A+B, 1 RS485 communication


AMC100-KD48
Dry contact, monitor the switching status of 48branches A+B, 1 RS485 communication
AMC100-FT30
1 way RS485 communication, 30 way temperature measurement
AMC100-FT48
1 way RS485 communication, 48 way temperature measurement
Function
Description
Measurement
(Common)
Three-phase AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparent Power, Frequency, Zero ground
voltage, neutral line current
Measurement
(Power Quality)
total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest
coefficient (CF), telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity
Temp.&Humidity
Monitoring
Temperature Monitoring Range: -40ºC~+99ºC
Humidity Monitoring Range: 20%~90%
Leakage Current
2-channel Leakage Current Measurement
Accuracy
Electrical Parameter Metering Accuracy: Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric
energy level 1

Temperature Metering Accuracy: ±1ºC; Temperature Metering Accuracy: ±5%
Communication
RS485 Interface (MODBUS-RTU protocol)
DO
(Switch Output)
2-channel DO (Digital Output); 3A 250VAC/3A 30VDC
DI
(Switch Input)
6-channel DI (Digital Input); dry contact
Parameter
Description&Value
Voltage
Input
Rated Voltage
3x220~264Vac L-N
Reference Frequency
45~65Hz
Current
Input
Rated Current
3x1(6)A AC (via CTs)
Power
Supply
Source from
Voltage Input (Voltage signal input for both measurement and power supply)
Installation
DIN-rail
35mm standard DIN-rail Installation
Phase
Wiring
3P4W
3-phase 4-wire
Safety
Insulation
All terminals and the insulation resistance between the conductive pieces not less than 100MΩ
Withstand voltage
A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs,
the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover
Condition
Description&Value
Temperature
Operating Temperature: -20ºC~+55ºC; Storage Temperature: -40°C ~+70°C
Humidity
≤95%RH, no condensation, without corrosive gas
Altitude
≤ 2000m
Installation Instructions

Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485Acrel Amc100-Fak48 Multi Channel Digital AC Energy Meter Widely Used in Data Centers, Column Cabinets, etc. 1channel RS485

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier