• Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output
  • Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output
  • Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output
  • Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output

Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output

Certification: CE
Customized: Customized
Input: 100A-300A
Output: 50mA/100mA
Measuring Aperture: 20mm
Power Supply: ±15V
Samples:
US$ 11.2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
AHBC-LTA
Usage
Magnetic Sensor/Analog Sensor
Theory
Hall Sensor
Transport Package
Carton
Specification
68*57*20mm
Trademark
Acrel
Origin
China
Production Capacity
10000 Piece/Pieces Per Month

Product Description

1 Introduction
Hall current sensor is mainly used for isolated conversion of complex signals such as AC, DC and pulse.Through the principle of hall effect, the transformed signal can be directly collected and accepted by AD, DSP, PLC, secondary instrument and other devices.Hall current sensors are widely applicable for acquisition and feeback control of current signals in the current monitoring,inverter,solar power management,current cabinet,DC motor drive and UPS servo control systems.It has the advantages of fast response time, wide range of current measurement, high accuracy, strong overload ability, good linearity and strong anti-interference ability.


close type open ring hall effect current sensor with 100A-300A input 50mA/100mA output


2 Parameters

Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output
Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output




3.Product
Parameters Indicators
Rated input current ±10~±2000mA
Rated input voltage ±5V
Accuracy 1.0
Power supply DC±15V(Allow the volatility±20%)
Zero offset voltage ±20mV
Offset voltage drift ≤±1.0mV/ºC
Linearity 0.3%FS
Response time ≤300ms
Insulation voltage 2.5kV/50Hz/1min
Working temperature -40ºC~85ºC
Storage temperature -40ºC~85ºC
Power consumption ≤0.5W

Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output

Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output




Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output



Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output








Ahbc-Lta Close Loop Current Transducer 100A-300A Input 50mA/100mA Output
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
304
Year of Establishment
2003-06-23