Customization: | Available |
---|---|
Warranty: | 2 Years |
Display: | LCD Display |
Still deciding? Get samples of US$ 46.2/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measurement: 3-phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
Accuracy: 0.5% (kWh)
Frequency: 45~65Hz
Rated Voltage: 3x380~456Vac L-L (direct connect); 3x100~120Vac L-L (via PTs)
Rated Current: 3x10(80)A AC (direct connect); 3x1(6)A AC (via CTs)
Communication: RS485 (MODBUS-RTU)
Harmonic: 2~31st and total Harmonic
Standard&Certificate: IEC; CE;CE-MID; EAC
Multi-rate: 4 Tariff Rates and etc
Data Function: Frozen Data, Max Demand,etc
Diverse Electric Parameters Measurement kWh (3-phase positive Kilowatt-hours) kVarh (Kilovar-hours) Harmonic (2~31st voltage¤t)---Standard U (3-phase Voltage);I (3-phase Current);P (Power);Q (Reactive power);F (Frequency);S (Apparent power);PF (Power factor)
|
||
|
||
HMI for Common Configuration PT or CT ratio Wiring methods (3P4W or 3P3W) Back linght time RS485 (MODBUS-RTU) communication setting |
Technical parameter
Project
|
Performance parameter
|
||
Specification
|
3 phase 3 wires, 3 phase 4 wires
|
||
Measurement
|
Voltage
|
Reference voltage
|
3×100V\3×380Vac,3×57.7/100Vac, 3×220/380Vac (Can normally work under 1.2 times of rated voltage)
|
Consumption
|
<10VA(Single phase)
|
||
Impedance
|
>2MΩ
|
||
Accuracy class
|
Error±0.2%
|
||
Current
|
Input current
|
3×1(6)A, 3×10(80)A
|
|
Consumption
|
<1VA Single phase rated current
|
||
Accuracy class
|
Error±0.2%
|
||
Power
|
Active, reactive, apparent power, error±0.5℅
|
||
Frequency
|
45~65Hz,Error±0.2%
|
||
Metering
|
Energy
|
Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2)
|
|
Clock
|
≤0.5s/d
|
||
Digit signal
|
Energy pulse output
|
1 active photocoupler output
|
|
Pulse
|
Width of pulse
|
80±20ms
|
|
Pulse constant
|
400imp/kWh,10000imp/kWh(Correspond with the basic current)
|
||
Communication
|
Interface and communication protocol
|
RS485:Modbus RTU
|
|
Range of Communication address
|
Modbus RTU:1~ 247;
|
||
|
Baud rate
|
1200bps~19200bps
|
|
Environment
|
Working temperature
|
-25ºC~+55ºC
|
|
Relative humidity
|
≤95℅(No condensation)
|
Direct Connect Type
PIN/Terminal Overview of ADL400 (Direct Connect Type)
|
|
Power Wiring: 3-phase 4-wire via direct connect |
Power Wiring: 3-phase 3-wire via direct connect |
CT Operated Type
PIN/Terminal Overview of ADL400 (CT Operated Type)
|
|
Power Wiring: 3-phase 4-wire CT operated |