Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function
  • Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function
  • Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function
  • Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function
  • Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function
  • Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
APM510
Electric Equipment
Three Phase Four Wire
Trademark
Acrel
Origin
China

Product Description

Product Description

APM5 series network power meter (hereinafter referred to as the meter) is designed according to IEC international standards, with full power measurement, power statistics, power quality analysis (including harmonics, flicker), fault recording function (including voltage temporary rise and fall interrupt, inrush current and other records), event recording function and network communication and other functions. It is mainly used for comprehensive monitoring of power supply quality in the power grid. This series of meters is equipped with feature-rich DI/DO modules, AO modules, wireless communication modules, leakage temperature measurement modules, which can flexibly realize the full electrical circuit Power measurement and switching status monitoring. Product model specifications and functions.
Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function

Product Parameters
Measured
parameters
Total electrical measurement
Four-quadrant energy,Split phase electricity,Apparent energy,Multi-rate energy
Pulse output of energy
Total active ,Total reactive energy pulse output (72 type only has active energy pulses)
 
 
Demand
Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
Extreme
value statistics
Current, line voltage, phase voltage, active power, reactive power and other electrical parameters extreme values of this month
and last month (including time stamps)


Power quality
Unbalance of current, line voltage, phase voltage
Voltage phase angle, current phase angle
Total (odd, even) harmonic content of voltage and current
Harmonic content of voltage and current (2-63 times)
Interharmonic (included with option S).
Flicker (included with S option).
Voltage peak coefficient
Telephone waveform factor
Current K-factor
Vector
Voltage and current waveform
Fundamental voltage and current
Fault waveform recording
Record of voltage ramp-up and drop interruptions, inrush currents, etc. (included with S option).
Event logging
DIDO records, which can record the last 128 DID records
Alarm logging
The last 128 alarm records can be recorded
Communication
Modbus - RTU protocol, DL/T 645-2007 statute
Switching value
72 Shape: 2 channels of switching input + 2 channels of switching output;
96 Shape: 4 switching inputs + 2 switching outputs
Base model
Basic function
Optional function
Option Group
APM510
2DI2DO1EP1C
1. CE (Ethernet Communication/MODBUS-TCP).
1+5+6+7+8
2+3+4+7+8
5+6+7+8+9
5+6+7+8+10
5+6+7+8+11
5+6+7+8+12
2.2C (Extended 2nd Communication).
3.K (2 switch inputs + 2 switch outputs).
4.2M (2ch analog).
5.T (4-channel NTC temperature measurement).
6.L (1 channel leakage).
7.F (Compound Rate).
8.S (0.2S level + fault recording).
9.WF(WiFi Communication)
10.LR(Lora Communication)
11.4G(4G Communication)
Base model
Basic function
Optional function
Option Group
APM520
4DI2DO2EP1C
1. CE (Ethernet Communication/MODBUS-TCP).
1+5+6+7+8
2+3+4+7+8
1+5+6+7+8
2+3+4+7+8
5+6+7+8+9
5+6+7+8+10
5+6+7+8+11
5+6+7+8+12
Display
Display method
Dot matrix liquid crystal; Switch between Chinese and English
 
Resolution
128*128;
 
Backlight
White LED;
 
Visible area
72 Shape: 38mm*46mm (1.78"/2.3");
96 Shape: 56mm*60mm (2.46"/3.2");
 
Signal
Electrical network
Three-phase three-wire, three-phase four-wire, see the wiring diagram;
 
Frequency
45~65Hz;
 
Voltage
Rating: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only);
 
 
Overload: 1.2 times the rating (continuous); 2x rating/1 second;
 
 
Power consumption: < 0.5VA(Every way);
 
Current
Ratings: AC 3x 1 (1.2) A, AC 3x5(6)A;
 
 
Overload: 1.2 times the rating (continuous); 10x rating/1 second;
 
 
Power consumption: < 0.5VA(Every way);
 
Measurement accuracy
Voltage, current
IEC 61557-12 0.2%
 
Measurement accuracy
Voltage, current
IEC 61557-12 0.2%
 
Voltage harmonics, current harmonics
IEC 61557-12 1%
 
Frequency
IEC 61557-12 ±0.02Hz
 
Active power
IEC 61557-12 0.5%
 
Reactive power
IEC 61557-12 1%
 
Active electrical energy
IEC 62053-22 0.5S class (0.2S accuracy when S is selected).
 
Reactive power
IEC 62053-24 Class 1
Power quality (only available when S is selected).
Waves recording
20 waveforms, 10 waves before and after;
 
Waveform capture
128 cycle points are stored per waveform;
Switch input
Dry contact input, built-in power supply;
Response time: less than 300ms
Relay output
Contact type: normally open contact;
Contact capacity: AC 250V/3A DC 30V/3A;
Energy pulse output
Output mode: photocoupler pulse with open collector;
Pulse constant: 10000imp/kWh (default);
communication
RS485 interface/Modbus-RTU protocol and DLT645 protocol;
RJ45 interface (Ethernet)/Modbus-TCP protocol;
Wireless interface
power supply
Working range: AC 85V~265V; DC100V~350V
Power consumption: power consumption≤15VA;
Safety
Power frequency withstand voltage
The power frequency withstand voltage between the housing and the auxiliary power supply, each input and output terminal group is
AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input terminal and each output terminal group is
AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the terminal groups of switching input, communication, analog output and pulse
output is AC 1kV/1min;
 
Insulation resistance
Inputs,outputs to the shell>100MΩ;
Electromagnetic compatibility
Complies with IEC 61000 standard (Level 4);
Environment
Operating temperature:-25ºC~+70ºC;Storage temperature:-40ºC~+85ºC;
Relative humidity:≤95% without condensation;Altitude:≤2500m;
Protection Level
Display panel IP54; (Optionally IP65).
Standards
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Environmental Testing Part 2-2:Tests Test B:Dry heat
Environmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h)
IEC 61000-4
Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12
Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1 500V d.c -Equipment for testing, measuring or
monitoring of protective measures - Part12:Performances measuring and monitoring devices(PMD)
IEC 62053-22
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2S and 0.5S)
IEC 62053-24
Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency
(classes 0.5S 1S and 1)
Acrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording FunctionAcrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording FunctionAcrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording FunctionAcrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording FunctionAcrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording FunctionAcrel Network Power Meter Apm510 with Full Power Measurement, Power Statistics, Power Quality Analysis Fault Recording Function

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now