Acrel ASCB1 series intelligent micro circuit breakers are applied to low-voltage terminal distribution networks in industrial, commercial, civil buildings and infrastructure fields in residential buildings and similar places. The intelligent micro circuit breaker is used with the intelligent gateway to conduct real-time monitoring of the key electrical parameters of the power line, such as voltage, current, power, temperature, leakage, energy consumption, etc., and has remote control, abnormal warning, accident trip warning alarm, electric energy metering statistics, fault positioning and other functions. This series of products can be selected from 1 pole, 2 poles, 3 poles, 4 poles.
Model
|
ASCB1-63
|
ASCB1LE-63
|
||
Pole
|
1P/2P/3P/4P |
2P/4P
|
||
Grade of Shell
|
63A
|
|||
Rated Voltage
|
230V(1P/2P),400V(3P/4P)
|
|||
Rated Current
|
6A,10A,16A,20A,25A,32A,40A,50A,63A
|
|||
Instantaneous Unbuckle
Typ |
C/D
|
|||
Rated Short-circuit
Breaking Capacity |
6000A
|
|||
Protec
t |
Over
current Protection |
Default 100% rated current alert,
110% Rated current trip with adjustable threshold |
||
Short
circuit Protection |
5-10 Rated current for 0.04 seconds for circuit break
protection |
|||
Overload
Protection |
Default 100% rated power alert,110% Rated power trip with
adjustable threshold |
|||
Over
voltage Protection |
Default 110% rated voltage alert,120% rated voltage trip with
adjustable threshold |
|||
Under
voltage Protection |
Default 90% rated voltage alert,80% rated voltage trip with
adjustable threshold |
|||
Over
temperature Protection |
Default 80ºC alert,100ºC trip, the threshold is adjustable
|
|||
Leakage
Protection |
No
|
Default 20mA alert, 30mA trip,
the threshold is adjustable |
||
Leakage self
Inspection |
No
|
Manual button self-inspection
|
||
Mechanical Life
|
20000 times
|
|||
Electrical Life
|
6000times
|
|||
Levels of
Protection |
IP20
|
|||
Connection
Capacity |
1-35mm²
|
|||
Elevation
Requirements |
2000m
|
|||
Ambient
Temperature |
-10ºC~55ºC,the average temperature at 24h was no higher
than 40ºC |
|||
Environmental
Requirements |
No explosion hazard, no conductive dust, no sufficient
corrosion of metal and damaged insulation, no significant vibration |
|||
Relative Humidity
|
At + 40ºC, the relative humidity of the air is 50% and can
have high relative humidity at lower temperatures |
|||
Storage
Temperature |
-20ºC-70ºC
|
|||
Class of Pollution
|
II
|
|||
Installation Type
|
III
|
|||
Way to Installation
|
Standard 35mm guide rail installation
|