Parameter |
Description&Value |
|
Measurement
|
kWh&kVarh |
Total active kWh (bidirectional --positive and negative in total) |
Electrical Parameters |
U (Voltage), I (Current), P (Active Power), Q (Reactive Power),S (Apparent Power), PF (Power Factor), F (Frequency) |
|
Function Mode
|
Prepaid Mode |
Meter will shut down the power once the credit balance is below zero. (Data like credit balance is saved in the meter) |
Postpaid Mode |
Meter won't shut down the power once credit balance is below zero. (Can remotely control the meter to shut down the power by using Prepaid System) |
|
Mode Change |
Meter can change the mode between prepaid and postpaid by receiving the command from prepaid system |
|
Control
|
Auto-tripping Control |
Auto-tripping control is processed by the built-in high-capacity holding relay of the meters to realize on-off control of circuits breaker, also, this type of control will only be triggered when meter is in Prepaid Mode |
Remote Control |
Remote control will be commanded by prepaid system. When users give the command of switch on-off to a certain meter, this command will be send to meters through wireless communication and finally meter will shut down or recover the power after receiving the command. This type of control can be done when meter is in Postpaid Mode |
|
Multi-rate
Multi-Tariff
|
Optional Function |
4 tariff rates (spike, peak, valley, flat); 14-time intervals by day |
Input
Voltage
|
Rated Voltage |
3x380~456Vac L-L (Voltage signal input will be also served as power supply for meters) |
Frequency |
45~65Hz |
|
Consumption |
<4VA (each phase) |
|
Input
Current
|
Rated Current |
3x10(80)A AC (direct connection); 3x1(6)A AC (connected via CTs) |
Starting Current |
0.004 Ib (direct connection); 0.002 In (connected via CTs) |
|
Accuracy
|
Measurement |
Class 0.5s |
Clock |
≤0.5s/d |
|
Pulse
|
Pulse Width |
80ms±20ms |
Pulse Constant |
6400imp/kWh (direct connection); 400imp/kWh (connected via CTs) |
|
Communication
|
RS485 Interface |
MODBUS-RTU Protocol |
Infrared |
Used for Meter Reading |
|
HMI
|
LCD Display |
8 bits section LCD display |
Keypads Programming |
Setting of communication, current ratio and etc. |
|
Mechanical Feature
|
Outline Dimension (L*W*H) |
72mm*88mm*70mm |
Max Wiring Ability (with Flexible Cable) |
25mm2 |
|
Environment
|
Operating Temperature |
-25ºC~+55ºC |
Storage Temperature |
-40ºC~+70ºC |
|
Humidity |
≤95% (No condensation) |
|
Altitude |
<2000m |