Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close

Product Details
Customization: Available
Function: Protection
Condition: New
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
  • Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
  • Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
  • Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
  • Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
  • Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AM5SE-D2
Input Current
1A/5A
Display
LCD
Power Supply
AC/DC110V 220V DC48V
Load
Medium Power Relay
Action Principle
Electronic Type
Type
Electric Parameter Relay
Input Voltage
AC100V
Communication
2RS485
Trademark
Acrel
Origin
China

Product Description

Product Description

AM5 series microcomputer protection device are applicable to the user substation which the input voltage is 35kv or above. AM5 can be used to protect and control the user substation, and is be widely used to Power Industry, Water conservancy industry, Traffic Industry, Oil industry, Chemical industry,Coal Industry, Metallurgical Industry and so on.
Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close

Product Parameters
Power supply
Rated input
AC/DC220V, or AC/DC110V
Range
Rated Voltage×(1±20%)
Consumption
≤15VA ( DC )
Rated Voltage
Rated input
AC 100V/100/√3V
Range
1~120V
Accuracy
±0.5%
Consumption
≤0.5VA (single phase)
Rated Current
Rated input
AC 5A /1A
Range
0.04In~15In
Accuracy
±0.5%
Consumption
≤0.5VA (single phase)
Frequence
Rated frequency
50Hz or 60Hz
Range
45~55Hz or 60Hz
Accuracy
±0.1Hz
DI
Rated Voltage
AC/DC220V, or AC/DC110V
Range
Rared Voltage×(1±20%)
Consumption
≤1W(DC220V)(single channel)

DO
Mechanical life
≥10000
Switching capacity
≥1000W,L/R = 40ms
On current
continuous ≥5A,short time (200ms) ≥30A
Interrupting capacity
≥30W,L/R = 40ms
Environment
Temperature
-10ºC~+55ºC
Humidity
5%~95% (No condensation and freeze inside)
Altitude
≤2500m
Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and CloseDimension
Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
Installation Instructions

 

Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and CloseAcrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and CloseNetwork
Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and CloseApplication
Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and CloseAcrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
Certifications

 

Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close
Company Profile

Acrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and CloseAcrel Two-Turn Variable Differential Protection Measurement Control Device Am5se-D2 Numbers of Circuit Breaker Trip and Close

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier