Product Highlights

  • Wide Current Measurement Range: Supports rated input from 0 to 1500A with flexible options.
  • High Accuracy Class 1.0: Ensures precise signal conversion with linearity within 0.2%FS.
  • Fast Response Time: Response time is less than 5 microseconds for real-time monitoring.
  • Strong Anti-Interference: Designed with high isolation voltage of 3.5kV for stable operation.
  • Full Customization Available: Offers full, minor, and flexible customization from samples or designs.
  • Versatile Application Scope: Suitable for inverters, solar systems, UPS, and DC motor drives.
  • 100% Product Inspection: Every finished product undergoes visual and functional inspection.
  • ISO Certified Manufacturer: Certified with ISO9001, ISO45001, and ISO14001 standards.

Product Images of Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA

Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA pictures & photos
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA pictures & photos
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA pictures & photos
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA pictures & photos
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA pictures & photos
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA pictures & photos
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
    Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
    Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
    Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
    Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
    Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
  • Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA
    Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA

Find Similar Products

Product Description

Product Description

Hall current sensors are mainly suitable for the isolation and conversion of complex signals such as AC, DC, and pulse. Through the principle of Hall effect, the converted signals can be directly collected and accepted by various acquisition devices such as AD, DSP, PLG, and secondary instruments. They are widely used in current monitoring and battery applications, inverter power supply and solar power management systems, DC panels and DC motor drives, electroplating, welding applications, frequency converters, UPS servo control and other system current signal acquisition and feedback control. They have the advantages of fast response time, wide current measurement range, high accuracy, strong overload capacity, good linearity, and strong anti-interference ability.
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA

Product Parameters
Type
Rated current ratio(A)
Rated Output
Power Supply
AHKC-EKC
DC0~(500-1500)A
4-20mA
12V/24V
Parameters
Index
Rated Input Current
0~(50-500)A
Rated Output Voltage
5V/4V
Accuracy Class
1.0
Power Voltage
±15V
Zero Offset Voltage
±20mV
Offset Voltage Drift
≤±1.0mV/ºC
Linearity
≤0.2%FS
Response Time
≤5us
Bandwidth
0~20kHz
Isolation Voltage
3.5kV/50Hz/1min
Operating Temperature
-40ºC~85ºC
Storage Temperature
-40ºC~85ºC
Consumption
≤0.5W


Environment
Temperature
Operating Temperature: -25~+50ºC Storing Temperature: -40~+80ºC
Humidity
≤90%(No condensation)
Altitude
≤2500m
Acrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mAAcrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mAAcrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mAAcrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mAAcrel Ahkc-Ekca Split Core Open-Loop Hall Current Sensor Rated Input DC0- (500-1500) a Output 4-20mA

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR244735". Items marked "verified" are certified.

Watch Video
Watch Video
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.
ACREL CO., LTD.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 253 Yulv Road, Jiading District, Shanghai, China
verified Plant Area
15811.7 square meters
verified Number of Employees
291
verified Registered Capital
214,716,125 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
1500

Our Production Capability & Technical Expertise

verified Main Products
Energy Meter, Transformer Current, Temperature&Humidity Controller, Medical It System, Active Power Filter, Static Var Generator, Charging Pile
verified Production Lines
18
verified Production Machines
SMT Production Line, DIP Assembly Line, Automatic Electricity Sensor Production Line, Automatic Debugging and Testing Equipment
verified QA/QC inspectors
73 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified R&D Engineers
131 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2003-06-23
verified Export Year
4 Years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Australia, Domestic
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
50
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO45001:2018, ISO14001
verified Cooperated with Fortune 500
No

FAQ

What is the output signal type?
The sensor provides an analog output signal of 4-20mA.
What is the rated input current range?
The rated input current ranges from 0 to 1500A.
What is the accuracy class of this sensor?
The accuracy class is 1.0.
What is the response time of the sensor?
The response time is less than 5 microseconds.
Is customization available for this product?
Yes, full customization, minor customization, and flexible customization are available based on samples or designs.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
What is the lead time for production?
The lead time is within 15 working days for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now