Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
  • Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
  • Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
  • Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
  • Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
  • Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
Find Similar Products

Basic Info.

Model NO.
Adl200
Specification
72mm*71.5mm*92.6mm
Trademark
acrel
Origin
China

Packaging & Delivery

Package Size
30.00cm * 28.00cm * 20.00cm
Package Gross Weight
2.000kg

Product Description

Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PVSingle Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV
Overview
ADL200 single phase electric meter is designed for single phase active energy measurement on low voltage system,
in the same time it can measure the electrical parameters like voltage, current, power and so on. There is also RS485 can be chosen. This electricity meter has advantages of smaller volume, high precision, good EMC, easily installing etc, All meters meet the related technical requirements of electricity meter in the IEC62053-21,IEC62053-22 standards.
Model
ADL200
 
 
 
Phase
Single phase
 
 
 
Rated voltage
AC220V
 
 
 
Consumption
≤10VA
 
 
 
Reference frequency
50HZ
 
 
 
Maximum current
80A
 
 
 
Starting current
0.0041b
 
 
 
Consumption
≤4VA
 
 
 
L*W*H(mm)
36*88*70 mm
 
 
 
Mounting
Din rail 35mm
 
 
 
Communication
RS485-MOBUS(C)
 
 
 
Working temperature
-20ºC~+60ºC
 
 
 
Storage temperature
-30ºC~+70ºC
 
 
 
Humidity
≤95%(without condensation)
 
 
 
Altitude
<2000m
 
 
 
Function
Function
Function description
Function provide
 
Measurement
of kWh
Single-phase active kWh (positive and negative), 3 months
historical energy data frozen storage
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
: Standard; : Optional
Measurement
of electrical
parameters
Voltage, Current, Active power, Reactive power, Apparent power,
Power factor and Frequency
 
LCD Display
8 bits section LCD display
 
Key
programming
3 keys to set parameters like code, address, baud rate, multi-tariff
and communication protocol
 
Pulse output
Active energy pulse output
 
Multi-tariff
Adapt 4 time zones, 2 time interval lists, 14 time interval by day
and 4 tariff rates
 
Communication
Communication interface: RS485, Communication protocol:
MODBUS-RTU
 
Product Paramenters
Input voltage
Reference
voltage
AC 220V
 
 
Reference
frequency
50Hz
 
 
 
Power
consumption
<10VA
 
 
 
Input current
Basic current
10A
 
 
Maximum
current
80A
 
 
 
Starting
current
4‰Ib
 
 
 
Consumption
<4VA
 
 
 
Measurement
performance
Accuracy of
measuring
1 class
 
 
000000.00~99999999kWh
 
 
 
 
Clock accuracy
Error≤0.5s/d
 
 
 
Active pulse
Pulse width
80± 20ms
 
 
Pulse constant
1000imp/kWh
 
 
 
Communicati
on
Interface
RS485(A+, B-)
 
 
Connection
mode
Shielded twisted pair conductors
 
 
 
Protocol
MODBUS-RTU
 
 
 
Outline
Length ×
Width ×
Height
90mm× 36mm× 65mm
 
 
Strong current
terminal
Torque
<1.8Nm
 
 
 
Temperature
range
Work
temperature
-25ºC~55ºC
 
 
Storage
Temperature
-40ºC~70ºC
 
 
 
Relative humidity
≤95%(No condensation)
 
 
 
Altitude
<2000m
 
 
 
wiring and installing
Single Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PVSingle Phase DIN Rail Multifunctional RS485 Modbus Energy Meter Adl200 Solar PV