Acrel Amb100-a Series Intelligent Bus AC Monitoring Device

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Still deciding? Get samples of US$ 104.3/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
  • Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
  • Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
  • Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
  • Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
  • Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
Find Similar Products
  • Overview
  • Product Description
  • Technical Data
  • Installation Instructions
  • Picture in Real Site
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
AMB100-A
Installation
DIN Rail
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters
Electric Equipment
Three Phase
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Rated Voltage
3*220/380VAC
CT
Amb100-a 5A/2.5mA 100A/20mA 400A/100mA 600A/100
Overloading
1.2
Input Frequency
45-65Hz
Auxiliary Power Supply
Triggered Upon Receipt of Request Signal
Communication
RS485/Modbus-RTU or Lora Antenna
Installation1
DIN35mm Rail
Transport Package
Carton
Specification
170*150*130mm
Trademark
Acrel
Origin
China
HS Code
8501109190
Production Capacity
5000

Product Description

AMB intelligent bus AC monitoring device
 
AMB intelligent bus AC monitoring device is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time. By virtue of 2 RJ45 communication ports (1 in and 1 out) and MODBUS-RTU protocol, it is easy and reliable to upload the monitoring data to the touch screen of the main controller for centralized monitoring, ensuring safe and reliable operation of the system. The smart bus bar monitor has several benefits such as flexible and convenient wiring so that it is a good substitution of the traditional centralized array cabinet.
 
Measured parameters Voltage, current, frequency, active power, inactive power, power factor, active energy, inactive energy, 2nd-63rd harmonic, temperature, leakage
Voltage Rated value 3x220/380VAC
Range ±20%
Overloading 1.2 times than the rated voltage value continuously or 2 times than the rated voltage value instantaneously per second
Current CT AMB100-A:5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA
AMB110-A:100A/20mA
Range 1%-120%
Overloading 1.2 times than the rated current value continuously or 10 times than the rated current value instantaneously per second
Input frequency 45-65Hz
Measurement accuracy Voltage/current:grade 0.2; active power/energy:grade 0.5; inactive power/energy:grade 1; temperature:±1ºC
Auxiliary power supply AMB100/110-A(/W):triggered upon receipt of request signal
AMB100/110-A(/W)-P1:follow the bus bar voltage
functions Temperature detection -20-150ºC
Leakage 0-1A
Digital input 2 dry-contact inputs
Digital output 2 relay outputs; contact capacity:3A/30VDC, 3A/250VAC
Communication Via RS485/Modbus-RTU or LORA antenna
Installation Use DIN35mm rail
Protection IP20
Pollution level 2
Environment Temperature/ humidity/ altitude Working temperature:-20-60ºC
Storage temperature:-25-70ºC
Relative humidity:93%
Altitude:2500m
Safety Insulation The minimum insulation resistance between all terminals and conductive components of the shell is 100MΩ.
Withstanding voltage When a voltage of 2kV AC is applied between the voltage/ current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min..
Electromagnetic immunity Electrostatic discharge immunity Class 4
Radio frequency electromagnetic immunity Class 3
Transient burst immunity Class 4
Surge immunity Class 4
 

Product Description

Acrel Amb100-a Series Intelligent Bus AC Monitoring Device

Technical Data


Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
 

Installation Instructions


Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
Acrel Amb100-a Series Intelligent Bus AC Monitoring Device
Acrel Amb100-a Series Intelligent Bus AC Monitoring DeviceAcrel Amb100-a Series Intelligent Bus AC Monitoring Device

 

Picture in Real Site


Acrel Amb100-a Series Intelligent Bus AC Monitoring Device

 

FAQ

Acrel Amb100-a Series Intelligent Bus AC Monitoring Device

 

Company Profile

Acrel Amb100-a Series Intelligent Bus AC Monitoring Device


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier