AMC200(L) DC multi-circuit intelligent power acquisition and monitoring device is mainly used for the full
electrical parameter measurement of multiple circuits, and can be connected to the current input of up to 12 single-phase
DC circuits at the same time. It can directly measure parameters such as voltage, current and power.
Technical Parameter
|
Technical Indicator
|
|||
Input
|
DC Voltage
|
One channel:DC -48V
|
||
DC Current
|
12 Channels Hall Current Sensor:Hall sensor secondary side DC 5V access
|
|||
State Grid Monitoring
|
One channel:DC 0-5V
|
|||
Overload
|
Voltage: 1.2 times for 1 second, 2 times for 1 second; Current: 1.2 times for 1
second, 10 times for 1 second |
|||
Frequency
|
Voltage,Current Class 0.5,Power Class 1.0
|
|||
Resolution
|
The voltage output accuracy is 0.01V, the current output accuracy is 0.01A, the
power output accuracy is 0.01kW, and the power output accuracy is 0.01kWh |
|||
Function
|
Basic Function
|
Monitoring equipment system time, total voltage, total output current, total power, total electrical energy, voltage of each sub channel, current of each sub channel, power of each sub channel, electrical energy of each sub channel; RS485 communication
|
||
Alarm Function
|
DC voltage output too low alarm, DC voltage output too high alarm, one-time power-off alarm, module voltage loss alarm, metering sub channel error alarm, internal program error alarm, clock error alarm, memory unit failure alarm, AC input power failure alarm
|
|||
Timing function
|
Support broadcast timing, remote timing calibration of metering module can be carried out through RS485 communication interface
|
|||
Communication
|
Single-channel RS485, the default baud rate is 9600bps, and can be set to 1200-9600bps. Communication protocol: YD/T1363 protocol or Modbus RTU protocol
|
|||
Hall power supply
|
A set of ±12V power output
|
|||
Humidity And
Temperature |
4 Channels NTC Temperature Monitoring:Temperature:-20-100ºC
(Accuracy±2ºC) Humidity:20-90%RH(Accuracy ±5%RH) |
|||
Auxiliary
power |
Voltage Range
|
DC -40V~-60V
|
||
Power consumption
|
The whole device≤2W (without Hall power supply output)
|
|||
Storage
|
It has the storage function of historical energy data and historical alarm
information |
|||
Insulation resistance
|
≥40MΩ
|
|||
Environment
|
Temperature
|
Working Temperature:-20ºC~+60ºC;Storage Temperature:-40ºC~+70ºC
|
||
Humidity
|
≤98% no condensation, no corrosive gas place
|
|||
Altitude
|
≤4000m
|