The AC and pulsed DC sensitive residual current monitor ASJ10(Type A and Type AC) from Acrel Electric is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault.
The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system.
• Residual current monitoring in earthed 2, 3 or 4-conductor systems
• Current monitoring of, in the normal case, de-energised single conductors
• Socket-outlet circuits for devices which are operated unattended for a long time and which may not fail
• Alarm systems, safety devices
• Air conditioning systems, EDP systems
• Cooling equipment with valuable frozen goods
• Canteen kitchens
• Monitoring of earthed power supplies for stray currents
• Impact on N conductors
• Trace heating systems
• AC and pulsed DC sensitive residual current monitor Type A according to DIN EN 62020
• r.m.s. value measurement (AC)
• Two separately adjustable response values
• Frequency range 45…65 Hz
• Start-up delay, response delay and delay on release
• Restart function
• Digital measured value display via LC display
• Measured value memory for operating value
• CT connection monitoring
• LEDs: Power On, Alarm 1, Alarm 2
• Internal/external test/reset button
• Two separate alarm relays (one changeover contact each)
• N/O or N/C operation and fault memory behaviour selectable
• Device self monitoring
• Sealable transparent cover
Monitor type | A type (AC and pulsed DC sensitive residual current) |
Power supply | AC/DC 85~265V |
Rated residual operating current IΔn | 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(A) |
Delay on release t | 0,, 0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S) |
Rated residual Non-operating current IΔn | 50%IΔn |
Rated frequency | 45~65Hz |
Contact | 2 |
Contact data | N/O or N/C, change-over |
AL1: 8A, AC 250A 5A, DC 30A AL2: 6A, AC 250A 5A, DC 30A |
|
Communication | RS485(Modbus RTU)(Ordering code: ASJ10L-LD1A) |
Measured-value memory for alarm value | 25 data-records |
Reset | button, remote or automatic |
Operating temperature | -25…+55 °C |