Acrel DIN Rail 35mm Leakage Fault Current Operated Relay Protective Device for Sale
Contact Supplier
Product Highlights
- Dual Response Values: Features two separately adjustable response values for prewarning and alarm stages.
- Wide Operating Current Range: Supports rated residual operating currents from 0.03A to 30A.
- Versatile Power Supply: Compatible with AC/DC 85~265V power supply for flexible installation.
- Adjustable Delay Settings: Offers configurable delay on release times ranging from 0.06s to 10s.
- Digital Display & Memory: Includes LC display for measured values and memory for operating data.
- Dual Alarm Relays: Equipped with two separate alarm relays with selectable N/O or N/C contacts.
- Self-Monitoring Function: Features device self-monitoring and CT connection monitoring for reliability.
- DIN Rail Mounting: Designed for standard 35mm DIN rail mounting for easy integration.
Product Attributes
- Customization
- Available
- Theory
- Electromagnetic Relay
- Usage
- Leakage Monitoring
- Model NO.
- ASJ10-LD1A
- Phase
- 3
- Electricity Type
- a
- Number of Pole
- N/a
- Load
- N/a
- Protective Characteristics
- N/a
- Action Principle
- Electromagnetic Type
- Size
- See Instruction
- Type
- Electric Parameter Relay
- Operating Current
- 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(a)
- Delay on Release Toff
- 0,, 0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S)
- Contact
- 2
- Power Supply
- AC/DC 85~265V
- Non-Operating Current
- 50%in
- Mounting Type
- 35mm DIN Rail
- Transport Package
- Carton
- Specification
- N/A
- Trademark
- Acrel
- Origin
- China
- Production Capacity
- 50000
- Package Size
- 26.00cm * 16.00cm * 16.00cm
- Package Gross Weight
- 0.300kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Acrel DIN Rail 35mm Leakage Fault Current Operated Relay Protective Device for Sale
Find Similar Products
Product Description
The AC and pulsed DC sensitive residual current monitor ASJ10(Type A and Type AC) from Acrel Electric is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault.
The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system.
• Residual current monitoring in earthed 2, 3 or 4-conductor systems
• Current monitoring of, in the normal case, de-energised single conductors
• Socket-outlet circuits for devices which are operated unattended for a long time and which may not fail
• Alarm systems, safety devices
• Air conditioning systems, EDP systems
• Cooling equipment with valuable frozen goods
• Canteen kitchens
• Monitoring of earthed power supplies for stray currents
• Impact on N conductors
• Trace heating systems
• AC and pulsed DC sensitive residual current monitor Type A according to DIN EN 62020
• r.m.s. value measurement (AC)
• Two separately adjustable response values
• Frequency range 45…65 Hz
• Start-up delay, response delay and delay on release
• Restart function
• Digital measured value display via LC display
• Measured value memory for operating value
• CT connection monitoring
• LEDs: Power On, Alarm 1, Alarm 2
• Internal/external test/reset button
• Two separate alarm relays (one changeover contact each)
• N/O or N/C operation and fault memory behaviour selectable
• Device self monitoring
• Sealable transparent cover
| Monitor type | A type (AC and pulsed DC sensitive residual current) |
| Power supply | AC/DC 85~265V |
| Rated residual operating current IΔn | 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(A) |
| Delay on release t | 0,, 0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S) |
| Rated residual Non-operating current IΔn | 50%IΔn |
| Rated frequency | 45~65Hz |
| Contact | 2 |
| Contact data | N/O or N/C, change-over |
| AL1: 8A, AC 250A 5A, DC 30A AL2: 6A, AC 250A 5A, DC 30A |
|
| Reset | button or remote |
| Operating temperature | -25…+55 °C |




More technical/commercial support, please contact me!
Waiting for your information!
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR244735". Items marked "" are certified.
Company Profile
Acrel Co., Ltd. [Stock Code: 300286. SZ] is a high-tech enterprise concentrating on research, production, sales and services. It mainly provides systemic solutions of energy efficiency management and electrical safety for users. 'Acrel' is equipped with the complete production lines from cloud platform software to sensors. Until now, it has more than 8000 sets systemic solutions used in China to help users to realize energy visual management, supply energy data services and improve electrical efficiency and safety. 'Acrel' has maintained steady growth since its listing in 2012. The company will adhere to the concept of 'innovation, high-efficiency, unity and honesty' and it provides more high-quality solutions, products and service for power system users and micro-grid.
Acrel Energy Management System includes various cloud platforms such as substation operation and maintenance, safety power management, environmental protection power supervision and prepaid management, and many kinds of monitoring and management systems such as intelligent transformer and distribution, power quality, building energy consumption, industrial energy, leakage fire alarm, fire power, fire door, emergency lighting and evacuation instructions, charging pile charge, data center power unit and environment variables, intelligent lighting and IT distribution insulation.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- No. 253 Yulv Road, Jiading District, Shanghai, China
-
Plant Area
- 15811.7 square meters
-
Number of Employees
- 291
-
Registered Capital
- 214,716,125 RMB
-
Terms of Payment
- LC, T/T
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR
-
Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shanghai Port
-
Minimum Order Quantity
- 1 Piece
-
Supply Chain Partners
- 1500
Our Production Capability & Technical Expertise
-
Main Products
- Energy Meter, Transformer Current, Temperature&Humidity Controller, Medical It System, Active Power Filter, Static Var Generator, Charging Pile
-
Production Lines
- 18
-
Production Machines
- SMT Production Line, DIP Assembly Line, Automatic Electricity Sensor Production Line, Automatic Debugging and Testing Equipment
-
QA/QC inspectors
- 73 people
-
Inspection Type for Finished Products
- 100% inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Have instructions and uniformly followed
-
Customization Options
- Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
-
ODM Service Available
- Yes
-
R&D Engineers
- 131 people
-
Traceability of Raw Materials
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2003-06-23
-
Export Year
- 4 Years
-
Main Markets
- North America, South America, Europe, Southeast Asia/ Mideast, Australia, Domestic
-
Repeat Buyers Choice
- 30%~50%
-
Number of Foreign Trading Staff
- 50
-
Overseas Agent/Branch
- Yes
-
New Products Launched in Last year
- Yes
Our Certifications, Standards & Industry Recognition
-
Cooperated with Fortune 500
- No
FAQ
- What is the rated residual operating current range?
- The device supports rated residual operating currents of 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, and 30 Amperes.
- What power supply voltage does the device accept?
- It operates on a wide voltage range of AC/DC 85~265V.
- Can the response delay be adjusted?
- Yes, the delay on release can be set to 0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, or 10 seconds.
- What type of mounting is supported?
- The device is designed for mounting on a 35mm DIN rail.
- Does the device have a digital display?
- Yes, it features a digital measured value display via an LC display.
- What are the contact configurations for the alarm relays?
- It includes two separate alarm relays with N/O or N/C operation and fault memory behavior selectable.
- Is the device suitable for earthed power supply systems?
- Yes, it is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems).
- What is the operating temperature range?
- The device operates within a temperature range of -25 to +55 degrees Celsius.
Send your message to this supplier
People who viewed this also viewed
-
US$112.00 / Piece
-
US$88.00 / Piece
-
US$311.50 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Power Monitoring and Protection
- ASJ Residual Current Relay
- Acrel DIN Rail 35mm Leakage Fault Current Operated Relay Protective Device for Sale
Related Categories
Hot Searches
- High Current
- Current Voltage Factories
- Current Control Factories
- Current Protection Factories
- Fault Current
- Voltage Current Relay
- Low Leakage Current
- Current Protection Relay
- Low Residual Current
- Residual Current Operated Relay Bulkbuy